Loadbank 48V-100A
- Automatic loadbank can operate automatically in many modes: Constant current mode (CC), constant power (CP), Constant resistan mode (CR)…
- Nominal voltage: 48VDC (max 60V)
- Rated Current 100A (max 125A)
- Used to test the capacity of DC power supplies with 48V voltage, 24V test current from 2A to 100A
- Loadbank 48V DC can be used to test and evaluate the capacity of 48VDC, 24V or 12V battery packs with a capacity of 20 AH to 1.000AH
Electronic load 48VDC-100A is often used to test UPS battery packs in the telecommunications, electricity, oil and gas industries…
The 48VDC -100A loadbank lines are manufactured by VIETPRO according to standards, all components we use are of European origin, Japan … meet industry standards for safety in operation and protection of equipment. at the highest level.
Loadbank can be used to check whether the DC 48V/100A power source meets the manufacturer’s specifications such as: Continuous operation time, voltage fluctuations allowed volts. DC, rated current (A) and maximum current declared by the manufacturer meet or not…
Loadbank is used to regularly check the battery pack 48VDC/1.000AH in use periodically to measure and evaluate the current capacity of the cells.
Loadbank VPR 48ABE100 is frequently used in the discharge cycle to restore capacity and test 1.2V, 2V cells of baterry bank UPSs in hydroelectric power plants, thermal power plants, oil and gas rigs such as: : TRANSFOMER UPS, MERGENCY LIGHTING UPS POWER, FGD UPS SYSTEM, LP CO2 UPS SYSTEM, AC/DC UPS DISTRIBUTION SYSTEM, AC/DC UPS DISTRIBUTION…
1 | Load bank product code | VPR D48ABE100 |
---|---|---|
2 | Description | DC load bank 48V/ 100A |
3 | Brand | VIETPRO |
4 | Nominal discharge current | 100A |
5 | Nominal voltage | 48VDC |
6 | Nominal power discharge | 4.8 kW |
7 | Initial upgrade on the same module | N/A |
8 | Upgrade the system by expanding more module | N/A |
9 | auxiliary power supply | Auto volt 80~220VAC |
10 | use main DC test source as auxiliary power | Option |
11 | Load bank type | Automatic operation |
12 | Automatic operation | Yes |
13 | Built-in manual control | No |
14 | Operation modes | CC, CP, CR, TL |
15 | Move | 4 wheels combined with handle |
16 | Material of cooling fan | Aluminum |
17 | Size (mm) | W240 x H410 x D680 |
18 | Number of manual control switches | ≥13 |
19 | Number of automatic control switches | 24 |
20 | Computer connect port | Yes |
21 | Download datasheet load bank 48VDC/̀100A | Load bank datasheet download |