Load bank 420VDC/1.000A

Loadbank 420VDC/ 1.000A

  • Loadbank can operate automatically in many modes: Constant current mode (CC), constant power (CP), Constant resistan mode (CR)…
  • Nominal voltage: 420VDC (max 500V)
  • Rated Current 1.000A (max 1.190A)
  • Used to test the capacity of DC power supplies with 420V voltage, 110V test current from 2A to 1.000A
  • Automatic loadbank 420V DC can be used to test and evaluate the capacity of 420VDC, 220V battery bank with a capacity of 20 AH to 10.000AH
    Electronic load 420VDC-1.000A is often used to test UPS battery bank in the telecommunications, electricity, oil and gas industries…
tải giả 420VDC/1.000A
loadbank 420vdc discharge curent 1.000A

The 420VDC -1.000A loadbank lines are manufactured by VIETPRO according to standards, all components we use are of European origin, Japan … meet industry standards for safety in operation and protection of equipment. at the highest level.

Loadbank can be used to check whether the DC 420V/1.000A power source meets the manufacturer’s specifications such as: Continuous operation time, voltage fluctuations allowed volts. DC, rated current (A) and maximum current declared by the manufacturer meet or not…

Loadbank is used to regularly check the battery pack 420VDC/10.000AH in use periodically to measure and evaluate the current capacity of the cells.

Loadbank VPR 420ABE500+ (1.000A) is frequently used in the discharge cycle to restore capacity and test 1.2V, 2V cells of baterry bank UPSs in hydroelectric power plants, thermal power plants, oil and gas rigs such as: : TRANSFOMER UPS, MERGENCY LIGHTING UPS POWER, FGD UPS SYSTEM, LP CO2 UPS SYSTEM, AC/DC UPS DISTRIBUTION SYSTEM, AC/DC UPS DISTRIBUTION…

VPR D420ABE500+ (1.000A/ 420kW) includes 1 main module 500A and 1 sub module to expand 500A

List of specifications load bank VPR D420ABE500+ (2 module/420VDC/ 1.000A)
1Load bank product codeVPR D420ABE500+ (2 module 1.000A)
2DescriptionDC load bank 420V/ 1.000A
3BrandVIETPRO
4Nominal discharge current1.000A
5Nominal voltage420VDC
6Nominal power discharge420kW
7Initial upgrade on the same moduleN/A
8Upgrade the system by expanding more moduleN/A
9auxiliary power supplyAuto volt 80~220VAC
10use main DC test source as auxiliary powerN/A
11Load bank typeAutomatic operation
12Automatic operationYes
13Built-in manual controlYes
14Operation modesCC, CP, CR, TL
15Move4 wheels combined with crane hook
16Material of cooling fanAluminum
17Size (mm)2 x W1340 x H1080 x D1780 (2 module)
18Number of manual control switches≥13
19Number of automatic control switches24
20Computer connect portYes
21Download datasheet load bank 420VDC/1.000ALoad bank datasheet download